ANAEROBIC BIOLOGICAL REACTOR - RANC
- DEPURATION
- PRETREATMENT
- ANAEROBIC REACTOR
- SLUDGE SEPARATION
- TREATED WATER
- SLUDGE GENERATION

1
DEPURATION
DEPURATION
Ideal treatment system to treat effluents with medium or high organic load that carry significant amounts of suspended solids and/or grease.
2
PRETREATMENT
PRETREATMENT
Sand separator: when there is a very high presence of sand in the water to be treated, a system for its removal is available, generally a sedimentation sand trap is installed, which will also serve as a support for the screens for the removal of coarse solids.
3
ANAEROBIC REACTOR
ANAEROBIC REACTOR
SIGMA-RANC upflow contact anaerobic reactor: biological reactor with absence of oxygen that works at low volumetric loads, achieving high COD and BOD5 reduction yields with a simple process, without mechanisms or internal clarifiers in the reactor, and integrating the geomembrane cover that acts as a gasometer. The degraded organic matter is transformed into treated water and biogas.
4
SLUDGE SEPARATION
SLUDGE SEPARATION
The separation of the anaerobic sludge from the reactor is carried out in an external SIGMADAF clarifier, which is equipped with a sealed cover to recover the biogas released.
5
TREATED WATER
TREATED WATER
The treated water has low organic matter loads and can be introduced into a subsequent aerobic biological reactor with reduced dimensions and consumption.
6
SLUDGE GENERATION
SLUDGE GENERATION
The generation of excess sludge from anaerobic systems is very low and purging is minimal.
Wastewater treatment using anaerobic reactors RANC
The process offered by AGUA SIGMA under the name of SIGMA-RANC is suitable for the treatment of effluents with medium and high organic load, which carry significant amounts of suspended solids, as well as oils and fats. This equipment consists of a contact anaerobic biological reactor, with upflow, operating in the absence of oxygen at low volumetric loads.
It is a simple system, without internal mechanisms or clarifiers, which allows to achieve significant reductions of COD and BOD in the wastewater. The set integrates a geomembrane in its upper zone that acts as a biogas accumulator (Gasometer).
After biological purification, a clarifier is installed. SIGMADAF which will separate the remaining suspended solids and will be evacuated as excess sludge. In the anaerobic process the production of this sludge is minimal. The clarifier also includes a sealed cover in order to collect the biogas migrating from the anaerobic reactor system.
If the desired reduction of organic matter in the anaerobic reactor is not achieved, an aerobic biological treatment system is then installed, which will be small in size and low in consumption since most of the BOD is eliminated in the RANC reactor.
Agua Sigma offers various types of biological reactors that can be manufactured in different configurations to suit the needs and characteristics of each project.
Anaerobic RANC treatment has the following advantages, among others:

- Reduced energy consumption: since no oxygen must be supplied to produce the biological degradation of organic matter (anaerobic bacteria).
- Biogas generation: as a renewable energy source, thus reducing CO₂ emissions. Biogas is produced as a result of the biological degradation of organic matter by anaerobic bacteria and can be used to generate energy, once purified.
- High performance of the anaerobic reactor: Our reactor does not include mechanical systems or internal decanter, so its volume is fully used to verify the biological duration operation.
- Small footprint: The space occupied by anaerobic reactors is much smaller than that of aerobic reactors, and in the case of the RANC type, the geotextile that covers both the reactor and the clarifier acts as a gasometer, thus further reducing the space required for its implementation.
- Little excess sludge: The anaerobic process produces hardly any excess sludge.


Interested in this solution?
Contact one of our sales representatives and we will get back to you within 48 hours.
Treatment line

Primary treatment
It is common to have a system of screens or sieves and a desander, if necessary, to protect the rest of the treatment plant and remove larger contaminants.
Secondary treatment
The pretreated effluent enters a SIGMA-RANC anaerobic reactor enclosed by a dome of geotextile material that prevents access to external air, while collecting the biogas generated in the reaction of the anaerobic bacteria with the organic matter that contaminates the wastewater. Anaerobic bacteria obtain their energy from organic substances and nutrients in the absence of oxygen. This is achieved mainly through fermentation processes.
The metabolic processes carried out by these bacteria include:
- Hydrolysis: Breakdown of macromolecules into simpler components.
- Acetogenesis: Production of acetic acid and other compounds.
- Methanogenesis: Production of biogas as end-product
The biogas generated contains methane, CO₂ and hydrogen sulfide. Once filtered and treated, it can be used for energy generation. This energy is part of the so-called "renewables", thus reducing the carbon footprint and the contribution of greenhouse gases.
The treated wastewater is subjected to clarification in a decanter with a geotextile cover that collects the remaining biogas and separates the little excess sludge that is produced.
Although the SIGMA-RANC reactors achieve a 90% reduction of COD in the effluents they treat, there are occasions when it is necessary to refine the remaining organic load; in such cases, it is common to install an aerobic biological reactor downstream.
A comparative scheme below shows advantages of the anaerobic process over the conventional aerobic process in terms of performance, consumption and waste production:
| Biological treatment | COD input(mg/l) | COD output(mg/l) | Energy | Excess sludge (Kg) |
|---|---|---|---|---|
| Aerobic | 1 Kg | 0.1 Kg | Consumes 1 kW | 0,6 |
| Anaerobic | 1 Kg | 0.1 Kg | Produces 0.3 m3 of CH4 | 0,1 |
Our anaerobic treatment system stands out as a robust solution, ideal for treating effluents with medium or high organic load that carry significant amounts of suspended solids and/or grease.
Working at low volumetric loads, high COD and BOD reduction performances are achieved with a simple process, without mechanisms or internal clarifiers in the reactor, and integrating the geomembrane cover that acts as a gasometer.
Anaerobic wastewater treatment is a process that is emerging as a sustainable and effective alternative for wastewater management.

Contact