FBR REACTOR: BIOLOGICAL AERATION TREATMENT + DAF SYSTEM
- PRETREATMENT OR PRIMARY TREATMENT WATER
- ANOXIC CAMERA
- AERATION CHAMBER
- DISSOLVED AIR FLOTATION (DAF)
- WATER
- LODO

1
PRETREATMENT OR PRIMARY TREATMENT WATER
ENTRY OF PRE-TREATMENT OR PRIMARY TREATMENT WATER
The water from the pretreatment stage enters the FBR reactor, which offers excellent performance for highly biodegradable and low sedimentation industrial water, which is difficult to separate in typical decanters.
2
ANOXIC CAMERA
ANOXIC CAMERA
In cases where there is a high concentration of nitrogen and/or nitrates are generated above the discharge limits, a modified biological system with an anoxic pre-chamber will be offered. This allows the simultaneous removal of nitrogen and organic matter.
3
AERATION CHAMBER
AERATION CHAMBER
Biological reactor with air injection and oxygen transfer for the degradation of organic matter by microorganisms. Biomass concentrations of up to 9 g/L are achieved in an FBR system, three to four times higher than conventional systems with secondary sedimentation.
4
DAF SYSTEM
DAF SYSTEM
Biomass is separated by flocculation and DAF flotation. The addition of polyelectrolyte to the clarification system generates easily separable biomass flocs and provides a high concentration of biomass within the reactor, resulting in higher performance than other suspended biomass systems. A coagulant can be added to reduce turbidity and precipitate phosphorus.
5
WATER
WATER
Perfectly clarified water that can be discharged in compliance with the discharge limits established by current regulations.
6
LODO
LODO
Part of the sludge generated is recirculated to the biological reactor to maintain a stable biomass concentration. The rest is extracted as a purge for further treatment or disposal.
Wastewater treatment using FBR reactors
Wastewater from many industries carries floating materials such as oils and fats, and tends to form low-density, spongy sludge that is difficult to settle. These discharges are commonly found in food industries such as slaughterhouses, poultry farms, and food processing plants, and are highly biodegradable.
AGUA SIGMA FBR reactors offer high performance in the treatment of this type of wastewater. This process combines an aerated biological reactor with a dissolved air flotation (DAF) system, which acts as an alternative to conventional secondary settling.
An FBR (Flotation Biological Reactor). It uses flotation to separate activated sludge from water and achieves concentrations of up to 9000 mg/L MLSS of biomass in the biological reactor.
SIGMA dissolved air flotation equipment produces perfectly clarified water that can be discharged in compliance with discharge requirements, and sludge that is partly recirculated to the biological reactor to maintain a stable concentration of active sludge, and partly extracted as purge.
With this special equipment, sludge with a dry solids content 3 or 4 times higher than any conventional system can be achieved. The treated effluent can be discharged into the sewer or, in many cases, reused.
Agua Sigma offers various types of biological reactors that can be manufactured in different configurations to suit the needs and characteristics of each project.
Some of the advantages of our FBR reactors are:

- High system reliability against typical sludge with poor sedimentation (bulking).
- Wide range of flow rates (from 50 to 10,000 m³/day).
- Ability to work at very high biomass concentrations in biological reactors (up to 9000 mg/L).
- Lower volume of biological reactors.
- The BIODAF system acts as a sludge thickener, so sludge treatment facilities will be smaller than in a conventional system.
- Ability to integrate post-treatments in the same unit.
- Perfect solution for plants that need to increase their size.


Interested in this solution?
Contact one of our sales representatives and we will get back to you within 48 hours.
Treatment line

Pretreatment or primary treatment
The primary treatment aims to separate materials that can be separated mechanically and physically. The most effective process combines physicochemical treatment with clarification using dissolved-air flotation systems.
For larger solids, screens and sieves with different mesh sizes can also be used.
The pretreatment stage removes a significant portion of the contaminants and prevents operational problems, while also reducing operating costs for the rest of the wastewater treatment plant. Furthermore, in many cases, it allows for the recovery of waste that can be reused as byproducts.
Other options include sand traps and degreasers, which are widely used in industrial water treatment.
Secondary treatment
The pretreated effluent contains suspended solids and dissolved substances, including salts and organic matter. This effluent is fed to a biological reactor in which air is blown in to provide the oxygen necessary for the bacteria to oxidize and eliminate the biodegradable organic matter. The biodegradation process is produced by the population of bacteria and nutrients that form a mixed liquor called "active sludge".
In the event that these sludges are spongy and have low density, they will tend to float, so that subsequent clarification by means of a conventional settling system would not be feasible, since many sludges would escape with the clarified water.
FBR technology replaces the secondary clarifier and provides a more efficient solution. The effluent from the biological reactor is fed into a dissolved air flotation (DAF) unit sized for this type of sludge. In this process, biomass flocs are formed and separated by flotation using microbubbles of air. The addition of polyelectrolyte to the clarification system allows the generation of easily separable biomass flocs, as well as providing a high concentration of active sludge within the reactor (9 g/l) and, consequently, higher performance than in other biological systems with suspended biomass. Optionally, a coagulant can be added to reduce turbidity and precipitate phosphorus.
This activated sludge is partly recirculated to the biological reactor to maintain a stable biomass concentration, and partly extracted as a blowdown.
In cases where there is a high concentration of nitrogen and/or nitrates are generated above the discharge limits, a modified biological system can be incorporated with an anoxic chamber upstream of the biological reactor. This allows the simultaneous elimination of nitrogen and organic matter by the process of nitrification - bacterial denitrification.
The perfectly clarified water may be discharged in compliance with the discharge requirements, or recovered for irrigation or for some processes of the industry that generates the effluent.

Contact